Sales ABB in Macedonia

Economize your outlays when recovering your machine in technical way thanks to ABB products. Products have modern technology rank as succesfully in many endustry deparments. Onrion LLC is not an authorized distributor, dealer or manufacturer of this brand. We offer you a large order possiblity with our suitable supply coorperatives and supplying way.

Who is the official distributor or seller of ABB in Macedonia?

Although we are not the official distributor or seller of ABB in Macedonia, we source our products from reliable channels and offer original ABB equipment at competitive prices.

Where can I buy ABB products in Macedonia?

You can purchase ABB products from Onrion LLC. We offer a wide range of original ABB products to meet your industrial needs.

How can I access ABB product catalogs, user manuals, technical documents, and PDFs?

You can access catalogs, user manuals, and technical documents for ABB products on our website. Visit the resources section or contact us directly for specific documents.

Do you provide a warranty for ABB products?

Warranty terms may vary depending on the product. Please contact us for detailed information about the warranty coverage of the ABB products you are interested in.

How can I get technical support for ABB products?

While we do not offer direct technical support, we can facilitate communication between you and the manufacturer to ensure you receive the necessary assistance.

Brand products ABB

CMA 135

Terminal plates; 110 Vca; Application: Communication interface;

CMA 136

Terminal plates; 110 Vca; Application: Communication interface;

D2D146-AA02-22 / 64650114

(Fan / fan D2D146-AA02-22 230VAC 50 / 60HZ 0.81 / 0,76A 290 / 280W 2250 U / min D2D146-AA02-22)

D674A906U01

Cartridge U-high HART/Std. FET 300

EHS 152.

single phase surge protection capacitors (0.25 micro farad)

FEP311

(Process Master)

FEP311 DN 100 (4 IN.)

Hot Water Supply BTU meter lining material A PTFE - Electrode Design Standard 1 - measuring electrode material S Stainless steel 1.4571 (316Ti) - Grounding accessories Standard 1 - Process fitting D2 flange DIN PN 16 - Process connection material steel B - certificates 0 measuring tube with PED approval - Calibration A standard accuracy - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - Signal cable length No cable 0 - Explosion protection Without A - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) - A cable gland M20 x 1.5 - Energy supply 1100 ... 230 VAC, 50 Hz - signal inputs and outputs C HART + 20 mA active + impulses + Contact in- / output - presets / diagnostics 1 Parameters are at factory settings / Standard diagnostic functions activated - Case H1 single-chamber housing

FEP311 DN 125 (5 IN.)

Lining Material A PTFE - Electrode Design Standard 1 - measuring electrode material S Stainless steel 1.4571 (316Ti) - Grounding accessories Standard 1 - Process fitting D2 flange DIN PN 16 - Process connection material steel B - certificates 0 measuring tube with PED approval - Calibration A standard accuracy - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - Signal cable length No cable 0 - Explosion protection Without A - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) - A cable gland M20 x 1.5 - Energy supply 1100 ... 230 VAC, 50 Hz - signal inputs and outputs C HART + 20 mA active + impulses + Contact in- / output - presets / diagnostics 1 Parameters are at factory settings / Standard diagnostic functions activated - Case H1 single-chamber housing

FEP311 DN 25 (1 IN.)

- A PTFE liner material - Electrode Design Standard 1 - measuring electrode material S Stainless steel 1.4571 (316Ti) - Grounding accessories Standard 1 - Process fitting D4 flange DIN PN 40 - Process connection material steel B - certificates 0 measuring tube with PED approval - Calibration A standard accuracy - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - Signal cable length No cable 0 - Explosion protection Without A - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) - A cable gland M20 x 1.5 - Energy supply 1100 ... 230 VAC, 50 Hz - signal inputs and outputs C HART + 20 mA active + impulses + Contact in- / output - presets / diagnostics 1 Parameters are at factory settings / Standard diagnostic functions activated - Case H1 single-chamber housing

FEP311 DN 50 (2 IN.)

- A PTFE liner material - Electrode Design Standard 1 - measuring electrode material S Stainless steel 1.4571 (316Ti) - Grounding accessories Standard 1 - Process fitting D4 flange DIN PN 40 - Process connection material steel B - certificates 0 measuring tube with PED approval - Calibration A standard accuracy - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - Signal cable length No cable 0 - Explosion protection Without A - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) - A cable gland M20 x 1.5 - Energy supply 1100 ... 230 VAC, 50 Hz - signal inputs and outputs C HART + 20 mA active + impulses + Contact in- / output - presets / diagnostics 1 Parameters are at factory settings / Standard diagnostic functions activated - Case H1 single-chamber housing

FEP311 DN 80 (3 IN.)

- A PTFE liner material - Electrode Design Standard 1 - measuring electrode material S Stainless steel 1.4571 (316Ti) - Grounding accessories Standard 1 - Process fitting D4 flange DIN PN 40 - Process connection material steel B - certificates 0 measuring tube with PED approval - Calibration A standard accuracy - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - Signal cable length No cable 0 - Explosion protection Without A - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) - A cable gland M20 x 1.5 - Energy supply 1100 ... 230 VAC, 50 Hz - signal inputs and outputs C HART + 20 mA active + impulses + Contact in- / output - presets / diagnostics 1 Parameters are at factory settings / Standard diagnostic functions activated - Case H1 single-chamber housing

FEP321 DN 250 (10 IN.)

- A PTFE liner material - Electrode Design Standard 1 - measuring electrode material S Stainless steel 1.4571 (316Ti) - Grounding accessories Standard 1 - Process fitting D2 flange DIN PN 16 - Process connection material steel B - certificates 0 measuring tube with PED approval - Calibration A standard accuracy - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - signal cable length 1 5 m (about 16 ft) standard cable - Explosion protection Without A - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) - A cable gland M20 x 1.5 - Energy supply 0 None - signal inputs and outputs Y Without - presets / diagnostics 1 Parameters are at factory settings / Standard diagnostic functions activated - Accessories AY Without

FEP321 DN 300 (12 IN.)

- A PTFE liner material - Electrode Design Standard 1 - measuring electrode material S Stainless steel 1.4571 (316Ti) - Grounding accessories Standard 1 - Process fitting D2 flange DIN PN 16 - Process connection material steel B - certificates 0 measuring tube with PED approval - Calibration A standard accuracy - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - signal cable length 1 5 m (about 16 ft) standard cable - Explosion protection Without A - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) - A cable gland M20 x 1.5 - Energy supply 0 None - signal inputs and outputs Y Without - presets / diagnostics 1 Parameters are at factory settings / Standard diagnostic functions activated - Accessories AY Without

FEP321 DN 400 (16 IN.)

- A PTFE liner material - Electrode Design Standard 1 - measuring electrode material S Stainless steel 1.4571 (316Ti) - Grounding accessories Standard 1 - Process fitting D2 flange DIN PN 16 - Process connection material steel B - certificates 0 measuring tube with PED approval - Calibration A standard accuracy - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - signal cable length 1 5 m (about 16 ft) standard cable - Explosion protection Without A - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) - A cable gland M20 x 1.5 - Energy supply 0 None - signal inputs and outputs Y Without - presets / diagnostics 1 Parameters are at factory settings / Standard diagnostic functions activated - Accessories AY Without

FEV111 DN 100 (4 IN.)

- Lining material Polypropylene V - Electrode type 1 Standard - measuring electrode material S stainless steel 316 - Grounding Accessories 3 1 grounding plate (stainless steel) - Process Connection Type S2 ISO 7005 PN 16 EN 1092-1 - Process connection material B Carbon Steel - certificates one measuring tube Standard (without PED approval) - Calibration A Standard factory calibration - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - Signal cable length 0 Without signal cable - Explosion protection A Common use (No explosion protection class) - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) integrated - A cable gland M20 x 1.5 - Energy supply 1100 ... 230 VAC, 50 Hz - signal inputs and outputs A + 20 mA HART pulse + + contact output - Configuration Type / Diagnostics 1 parameters to the factory Settings set /

FEV111 DN 150 (6 IN.)

- Lining material Polypropylene V - Electrode type 1 Standard - measuring electrode material S stainless steel 316 - Grounding Accessories 3 1 grounding plate (stainless steel) - Process Connection Type S2 ISO 7005 PN 16 EN 1092-1 - Process connection material B Carbon Steel - certificates one measuring tube Standard (without PED approval) - Calibration A Standard factory calibration - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - Signal cable length 0 Without signal cable - Explosion protection A Common use (No explosion protection class) - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) integrated - A cable gland M20 x 1.5 - Energy supply 1100 ... 230 VAC, 50 Hz - signal inputs and outputs A + 20 mA HART pulse + + contact output - Configuration Type / Diagnostics 1 parameters to the factory Settings set /

FEV111 DN 50 (2 IN.)

- Lining material Polypropylene V - Electrode type 1 Standard - measuring electrode material S stainless steel 316 - Grounding Accessories 3 1 grounding plate (stainless steel) - Process Connection Type S2 ISO 7005 PN 16 EN 1092-1 - Process connection material B Carbon Steel - certificates one measuring tube Standard (without PED approval) - Calibration A Standard factory calibration - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - Signal cable length 0 Without signal cable - Explosion protection A Common use (No explosion protection class) - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) integrated - A cable gland M20 x 1.5 - Energy supply 1100 ... 230 VAC, 50 Hz - signal inputs and outputs A + 20 mA HART pulse + + contact output - Configuration Type / Diagnostics 1 parameters to the factory Settings set /

FEV111 DN 80 (3 IN.)

- Lining material Polypropylene V - Electrode type 1 Standard - measuring electrode material S stainless steel 316 - Grounding Accessories 3 1 grounding plate (stainless steel) - Process Connection Type S2 ISO 7005 PN 16 EN 1092-1 - Process connection material B Carbon Steel - certificates one measuring tube Standard (without PED approval) - Calibration A Standard factory calibration - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - Signal cable length 0 Without signal cable - Explosion protection A Common use (No explosion protection class) - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) integrated - A cable gland M20 x 1.5 - Energy supply 1100 ... 230 VAC, 50 Hz - signal inputs and outputs A + 20 mA HART pulse + + contact output - Configuration Type / Diagnostics 1 parameters to the factory Settings set /

FEW321 DN 150 (6 IN.)

- A PTFE liner material - Electrode Design Standard 1 - measuring electrode material S Stainless steel 1.4571 (316Ti) - Grounding accessories Standard 1 - Process fitting D2 flange DIN PN 16 - Process connection material steel B - certificates 0 measuring tube with PED approval - Calibration A standard accuracy - temperature sensor / 1 standard / -20 ... 60 ° C Ambient temperature range (-4 ... 140 ° F) - A nameplate adhesive label - signal cable length 1 5 m (about 16 ft) standard cable - Explosion protection Without A - Protection transmitter / receiver 1 IP 67 (NEMA 4X) / IP 67 (NEMA 4X) - A cable gland M20 x 1.5 - Energy supply 0 None - signal inputs and outputs Y Without - presets / diagnostics 1 Parameters are at factory settings / Standard diagnostic functions activated - Accessories AY Without

FOCS OF 45 KA

CONTINUOUS CURRENT EQUIPMENT

FS00P0/802

CABLE PORT RS232 CONVERTER CABLE FORE REF 542 PLUS HMI UNIT, PARTS FOR "ABB" CONNECTION RELAY REF 610 ORDER NO: 1MRS050692, REV.B

FXE4000-DE41F(OBSOLETE REPLACED BY FEP311)

Flowmeter,Dn=200, Pn=10, PTFE, with converter

G60E00HKHF8LH6EM8NP6UUXXWRH

RELAY, TRANSFORMER MANAGEMENT, CONTACT RATING: 300 VDC 10 MA;COIL VOLTAGE: 125 TO 250 VDC 0.7A, TERMINAL: SCREW;MOUNT:PANEL,100 TO 240VAC, 50 60 HZ, 0.7A, WIRING DIAGRAM: 828726, INSTRUCTION MANUAL:1601-0114;